ACP (aluminium composite panel) cladding · 15 November 2026
How should ACP cladding be specified for Pacific Islands projects?
Specify ACP cladding for Pacific Islands projects as a complete external wall system, with coatings, fixings, supports and drainage selected for the site's salt exposure and weather conditions. Before pricing, confirm the proposed assembly's local approval requirements, wind design, fire performance and warranty conditions, rather than relying on a panel product sheet.
For a head contractor or QS, the key question is whether the quoted system suits the actual exposure. A lower panel rate can lose its appeal if the tender excludes suitable fixings, protective treatments or access for regular cleaning.
Why does coastal exposure change an ACP specification?
ACP, also called aluminium composite material or ACM, has aluminium skins bonded to a core. The core type, coating and fabrication details vary between products, so the material name alone does not define performance.
Salt deposits, humidity and wind-driven rain affect more than the visible panel face. They also affect rails, brackets, fasteners, flashings and other parts concealed behind the cladding.
Projects in Fiji, Samoa, Tonga, the Cook Islands and the Solomon Islands need site-specific assessment. A sheltered inland wall and an exposed beachfront facade should not automatically receive the same specification, even when they use the same panel colour.
What coating and warranty details should a QS check?
Ask for the exact panel manufacturer, product, coating system and proposed colour. A description such as 'PVDF finish' does not, by itself, establish suitability for the site's exposure or confirm warranty cover.
Obtain written confirmation of coastal suitability, including any distance-from-sea restrictions and exclusions for direct sea spray. Check whether the warranty distinguishes between coating adhesion, colour retention, chalking and corrosion.
Also check cleaning requirements, inspection duties and claim procedures. Confirm whether cover includes replacement material only or extends to removal, freight and reinstallation, because those costs can be substantial at a remote site.
We recommend recording these requirements in the tender comparison. Otherwise, two apparently similar panel prices may include very different obligations for the owner.
How do fixings and supports affect corrosion risk?
The visible panels are only one part of the corrosion assessment. The designer should specify suitable rails, brackets, anchors and fasteners for the exposure, including the interfaces between different materials.
Dissimilar metals can create corrosion risks when moisture is present. Isolation materials and protective treatments need to be compatible with the assembly and shown in the details, rather than left for the installer to resolve on site.
Do not accept 'stainless fixings' as a complete specification. Confirm the required grade, suitability for the exposure, structural capacity and compatibility with adjacent materials.
Ask how cut edges, drilled holes and damaged protective finishes will be treated where required by the system supplier. These small details belong in the priced scope.
How should ACP walls handle tropical rain and wind?
Establish whether the proposed assembly uses drained joints, sealed joints or another tested approach. The drawings should explain how water is managed at panel joints, openings, corners and the base of the wall.
Where a drained cavity forms part of the design, keep drainage paths clear and coordinate flashings with the wall behind. Sealant should serve its specified purpose, rather than compensate for missing flashings or poorly fitted panels.
Wind design must address the actual building and location. Panel spans, fixing centres, support spacing and anchors need project-specific confirmation, with attention to corners and edges where local pressures can be higher.
Allow for thermal movement through the manufacturer's fixing and joint details. Sun-exposed panels and their supports move as temperatures change, so restraint and clearances need deliberate design.
Does New Zealand compliance establish local approval?
New Zealand documentation can support a submission, but it does not automatically establish approval in another country. Confirm the applicable building requirements and acceptance process with the local designer and approving authority.
Fire performance needs a separate check from corrosion resistance. Identify the exact ACP core and obtain evidence relevant to the proposed wall assembly, building use and approval pathway.
An appraisal or test report should be checked for its scope and limitations. Evidence for one panel, fixing arrangement or substrate should not be assumed to cover a different assembly.
Agree the handover documents before award. These may include product traceability, inspection records, warranties and installation statements, with any PS3 or other producer statement requirements confirmed for the project.
Which coastal specification items should be priced separately?
Separate panel supply and fabrication from supports, fixings, flashings and isolation materials. This makes it easier to identify whether a proposed saving changes appearance, durability or the approved design.
Include freight, protective packaging, unloading and dry storage in the scope allocation. Confirm how panels will be supported and protected during transport, and follow the manufacturer's instructions for protective film removal.
Price replacement stock where appropriate, particularly for finishes that may vary between production batches. Agree quantities with the client rather than assuming future small orders will match or arrive quickly.
We have installed ACM since 2006. Our services include supply, QS sizing from drawings, cutting, rolling, CNC routing, grooving, fabrication, installation and site management.
What maintenance access should be designed before tender?
A coastal maintenance plan needs to be practical for the owner. Check how each elevation will be washed and inspected, including sheltered areas where rain may not remove salt deposits.
Use the panel and coating supplier's cleaning instructions to establish methods and frequency. Avoid promising a universal maintenance interval, because exposure and warranty conditions differ.
Provide access to inspect joints, flashings and visible fixings. Agree how damaged panels can be removed without unnecessary disturbance to adjacent work, and include the maintenance requirements in the handover documents.
What should you send us for a coastal ACP tender?
Send drawings, specifications, site exposure information and the proposed programme to tenders@kiwicladding.co.nz. Include available wind design and local approval requirements so we can identify scope gaps.
We work across the Pacific Islands, and tender emails reach our quantity surveyor directly.
Frequently asked questions
Is ACP suitable for beachfront buildings?
It can be, provided the complete assembly is specified for the exposure. Obtain written confirmation of coastal suitability and warranty conditions from the relevant suppliers.
Does a PVDF coating make ACP corrosion-proof?
No. Coating performance is only part of durability. Edges, fixings, supports, drainage and maintenance also need attention.
Can we substitute a cheaper ACP panel after tender?
Only after reviewing the alternative's core, coating, fabrication requirements and compliance evidence. Obtain the required design and approval acceptance before ordering.
Should the tender include spare ACP panels?
Consider them where replacement freight or colour matching could be difficult. Agree the quantity, storage arrangements and identification records with the client.
Have drawings to price? Send them to tenders@kiwicladding.co.nz or contact us.
All articles